Histological examination of drill sites in bovine rib bone after grinding in vitro with eight different devices
References
- . Vertebral-body biopsy. J Bone Joint Surg. 1956;38(A):93–102
- . Trephine biopsy of bone with special reference to the lumbar vertebral bodies. J Bone Joint Surg. 1949;31(A):146–149
- . Piezosurgery®: an ultrasound device for cutting bone and its use and limitations in maxillofacial surgery. Br J Oral Maxillofac Surg. 2004;42:451–453
- . The drill biopsy of bone lesions. Clin Radiol. 1972;23:536–540
- . Advantages of milling versus broaching the proximal femur. Orthopedics. 2005;28(Suppl.):s1041–s1044
- . Factors affecting bone healing following implant surgery. J Oral Implantol. 1996;22:7–11
- . Surgical drilling: design and performance of an improved drill. J Biomech Eng. 1982;104:245–252
- . The effect of drill-hole length on the primary stability of osteochondral grafts in mosaicplasty. Orthopedics. 2005;28:401–404
- . Manual punch versus power harvesting of osteochondral grafts. Arthroscopy. 2004;20:306–310
- . Treatment of acute fractures and fracture dislocations of the cervical spine by vertebral body fusion. A report of 11 cases. J Neurosurg. 1961;18:201–209
- . A biomechanical analysis of four different methods of harvesting bone-patellar tendon-bone graft in porcine knees. J Bone Joint Surg. 2002;84(A):1782–1787
- . Heat production by 3 implant drill systems after repeated drilling and sterilization. J Oral Maxillofac Surg. 2006;64:265–269
- . The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: a study of drill durability. Int J Oral Maxillofac Implants. 2004;19:335–349
- . Heat generation during implant site preparation: an in vitro study. Int J Oral Maxillofac Implants. 1997;12:186–193
- . Orthopaedic bone drills-can they be improved? Temperature changes near the drilling face. J Bone Joint Surg. 1996;78(Br):357–362
- . Experimental robotic milling in skull-base surgery. Comput Aided Surg. 2003;8:42–48
- . Effects of repeated drill use on temperature of bone during preparation for osteosynthesis self-tapping screws. Br J Oral Maxillofac Surg. 2005;43:314–319
- . Drilling efficiency and temperature elevation of three types of Kirschner-wire point. J Bone Joint Surg. 2002;84(Br):137–140
- . Temperature changes in bovine mandibular bone during implant site preparation: an assessment using infra-red thermography. J Dent. 1996;24:263–267
- . The effect of speed, pressure, and time on bone temperature during the drilling of implant sites. Int J Oral Maxillofac Implants. 1996;11:35–37
- . Effects of mechanical and thermal fatigue on dental drill performance. Int J Oral Maxillofac Implants. 2001;16:819–826
- . Investigation of variable factors in drilling bone. J Oral Surg. 1977;35:968–973
- . Eine neue Methode fuer Knochenbiopsien und Knorpel-Knochentransplantation [A new procedure for bone biopsies and cartilage and bone transplantation]. Sandorama. 1987;3:254–269
- . Bone marrow trephine biopsy. J Clin Pathol. 2001;54:737–742
- . The thermal effects of skeletal fixation-pin insertion in bone. J Bone Joint Surg. 1984;66(A):1077–1083
PII: S0266-4356(07)00004-6
doi: 10.1016/j.bjoms.2006.12.007
© 2007 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.