British Journal of Oral and Maxillofacial Surgery
Volume 47, Issue 6 , Pages 446-449 , September 2009

Accuracy of maxillary positioning in bimaxillary surgery

  • W.B. Kretschmer

      Affiliations

    • Department of Oral and Maxillofacial Surgery, Marienhospital, Stuttgart, Germany
    • Clinic of Cranio-Maxillofacial Surgery, University of Medicine and Pharmacy, Cluj-Napoca, Romania
    • Corresponding Author InformationCorresponding author at: Department of Oral and Maxillofacial Surgery, Marienhospital Stuttgart, Boeheimstr. 37, 70199 Stuttgart, Germany. Tel.: +49 711 6489 8261; fax: +49 711 6489 8262.
  • ,
  • W. Zoder

      Affiliations

    • Department of Oral and Maxillofacial Surgery, Marienhospital, Stuttgart, Germany
  • ,
  • G. Baciut

      Affiliations

    • Clinic of Cranio-Maxillofacial Surgery, University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • ,
  • Mihaela Bacuit

      Affiliations

    • Clinic of Cranio-Maxillofacial Surgery, University of Medicine and Pharmacy, Cluj-Napoca, Romania
  • ,
  • K. Wangerin

      Affiliations

    • Department of Oral and Maxillofacial Surgery, Marienhospital, Stuttgart, Germany

,Accepted 8 June 2009.

References 

  1. Turvey TA. Simultaneous mobilisation of the maxilla and mandible: surgical technique and results. J Oral Maxillofac Surg. 1982;40:96–99
  2. Song KG, Baek SH. Comparison of the accuracy of the threedimensional virtual method and the conventional manual method for model surgery and intermediate wafer fabrication. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2009;107:13–21
  3. Schneider M, Tzscharnke O, Pilling E, Lauer G, Eckelt U. Comparison of the predicted surgical results following virtual planning with those actually achieved following bimaxillary operations of dysgnathia. J Craniomaxillofac Surg. 2005;33:8–12
  4. Hohlweg-Majert B, Schön R, Schmelzeisen R, Gellrich NC, Schramm A. Navigational maxillofacial surgery using virtual models. World J Surg. 2005;29:1530–1538
  5. Donatsky O, Bjoern-Joergensen J, Holmqvist-Larsen M, Hillerup S. Computerized cephalometric evaluation of orthognathic surgical precision and stabilitiy in relation to maxillary superior repositioning combined with mandibular advancement or setback. J Oral Maxillofac Surg. 1997;55:1071–1080
  6. Stanchina R, Ellis E, Gallo WJ, Fonseca RJ. A comparison of two measures for repositioning the maxilla during orthognathic surgery. Int J Adult Orthodon Orthognath Surg. 1988;3:149–154
  7. Van Sickels JE, Larsen AJ, Triplett RG. Predictability of maxillary surgery: a comparison of internal and external reference marks. Oral Surg Oral Med Oral Pathol. 1986;61:542–545
  8. Neubert J, Bitter K, Somsiri S. Refined intraoperative repositioning of the osteotomized maxilla in relation to the skull and TMJ. J Craniomaxillofac Surg. 1988;16:8–12
  9. Gil JN, Claus JDP, Manfro R, Lima SM. Predictability of maxillary repositioning during bimaxillary surgery: accuracy of a new technique. Int J Oral Maxillofac Surg. 2007;36:296–300
  10. Wangerin K. Einzeitige bimaxilläre Korrektur extremer Fehlbisse: Vorbehandlung, Planung und Operationsmethode mit funktionsstabiler Fixierung im Ober- und Unterkiefer (One stage procedure for bimaxillary correction of extremely severe malocclusions. Pretreatment planning and operation methods with functionally stable fixation of upper and lower jaws), Dtsch Z Mund Kiefer Gesichtschir. 1990;14:424–432
  11. Ferguson JW, Luyk NH. Control of vertical dimension during maxillary orthognathic surgery. A clinical trial comparing internal and external fixed reference points. J Craniomaxillofac Surg. 1992;20:333–336
  12. Perkins SJ, Newhouse RF, Bach DE. A modified Boley gauge for accurate measurement during maxillary osteotomies. J Oral Maxillofac Surg. 1992;50:1018–1019
  13. Polido WD, Ellis E, Sinn DP. An assessment of the predictability of maxillary repositioning. Int J Oral Maxillofac Surg. 1991;20:349–352
  14. Ong TK, Banks RJ, Hildreth AJ. Surgical accuracy in Le Fort I maxillary osteotomies. Br J Oral Maxillofac Surg. 2001;39:96–102
  15. Ellis E. Accuracy of model surgery: evaluation of an old technique and introduction of a new one. J Oral Maxillofac Surg. 1990;48:1161–1167
  16. Obwegeser H. Surgical correction of small or retrodisplaced maxillae. The “dish-face” deformity. Plast Reconstr Surg. 1969;43:351–365
  17. Hunsuck EE. A modified intra-oral sagittal splitting technique for correction of mandibular prognathism. J Oral Surg. 1968;26:250–253
  18. Bjork A, Skieller V. Growth of the maxilla in three dimensions as revealed radio-graphically by the implant method. Br J Orthod. 1977;4:53–64
  19. Cope MR. Measuring changes in maxillary height during osteotomy surgery. Br J Oral Maxillofac Surg. 1994;32:257–259
  20. Kretschmer W. Die dreidimensional kontrollierte Verlagerung des Oberkiefers im Rahmen bignather Eingriffe mit Positionierungsplatten und Splinten. Kiel: Med. Dissertation; 1999.

PII: S0266-4356(09)00217-4

doi: 10.1016/j.bjoms.2009.06.004

British Journal of Oral and Maxillofacial Surgery
Volume 47, Issue 6 , Pages 446-449 , September 2009