Advertisement
Regular Article| Volume 39, ISSUE 1, P2-7, February 2001

Download started.

Ok

Continuous and intermittent bone distraction using a microhydraulic cylinder: an experimental study in minipigs

      This paper is only available as a PDF. To read, Please Download here.

      Abstract

      Distraction osteogenesis of the mandible is an option in the treatment of mandibular hypoplasia. Today, only intermittent distraction devices are available for clinical application. The aim of this study in minipigs was to evaluate continuous bone distra ction using a microhydraulic cylinder. After a seven-day interval, continuous or intermittent distraction of 1.5mm/day was established for 10 days. Immediately after active distraction, two animals and 20 days later the other four animals were killed and radiographs taken. The mandible was then removed en bloc and the distracted bone examined histologically. Inter mittent distraction forces of up to 2500kPa were necessary to move the cylinders' piston. The pressure needed for continuous distraction was considerably lower (1200–1300kPa). While the specific histological structure of the varying zones in the distraction gap was similar after continuous and intermittent distraction, bone healing was accelerated after continuous distraction as shown by ultrasonography and scanning elec tron microscopy.
      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to British Journal of Oral and Maxillofacial Surgery
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

      References

        • Steinhäuser E
        • Janson I
        Kieferorthopädische Chirurgie – Eine interdisziplinäre Aufgabe. Quintessenz, Bd I1988
        • Bell WH
        • Scheidemann GB
        Correction of vertical maxillary deficiency: stability and soft tissue changes.
        J Oral Surg. 1981; 39: 666-672
        • Bell WH
        • Epker BN
        Surgical orthodontic expansion of the maxilla.
        Am J Orthod. 1976; 70: 517-524
        • Cope JB
        • Samchukov ML
        • Cherkashin AM
        Mandibular distraction osteogenesis: a historic perspective and future directions.
        Am J Orthod Dentofacial Orthop. 1999; 115: 448-460
        • Schendel SA
        • Epker BN
        Results after mandibular advancement surgery: an analysis of 87 cases.
        J Oral Surg. 1980; 38: 265-282
        • Codivilla A
        On the means of lengthening in the lower limbs, the muscles and tissues which are shortened through deformity.
        Am J Orthop Surg. 1905; 2: 353-369
        • Abbot LC
        The operative lengthening of the tibia and tibula.
        J Bone Joint Surg. 1927; 9A: 128-135
        • Samchukov ML
        • Cherkashin AM
        • Cope JB
        Distraction osteogenesis: origins and evolution.
        in: McNamara Jr, JA Trotman CA Advances in Craniofacial Orthopedics, Vol. 34, Craniofacial growth series. University of Michigan, Center for human growth and development, Ann Arbor1998: 1-35
        • Ilizarov GA
        • Smelyshev NN
        Lengthening of the femur with simultaneous closed arthrodesis of the hip joint.
        Ortop Traumatol Protez. 1972; 33: 62-68
        • McCarthy JG
        • Schreiber JS
        • Karp N
        Lengthening the human mandible by gradual distraction.
        Plast Reconstr Surg. 1992; 89: 1-8
        • Klein C
        • Howaldt HP
        Mandibular micrognathism as a sequela of early childhood capitulum fractures and their treatment using distraction osteogenesis.
        Fortschr Kiefer Gesichtschir. 1996; 41: 147-151
        • Guerrero C
        Expansion mandibular quirurgica.
        Review Venezuela Ortodontica. 1990; 1: 48
        • McCarthy JG
        • Staffenberg DA
        • Wood RJ
        • Cutting CB
        • Grason BH
        • Throne CH
        Introduction of an intraoral bone-lengthening device.
        Plast Reconstr Surg. 1995; 96: 978-981
        • Guerrero C
        • Bell WH
        • Flores A
        • Modugno VL
        • Contasti G
        • Rodriguez AM
        Distraction osteogenica mandibular intraoral.
        Odontol al Dia. 1995; 11: 116-132
        • Chin M
        • Toth BA
        Distraction osteogenesis in maxillofacial surgery using internal devices: a review of five cases.
        J Oral Maxillofac Surg. 1996; 54: 45-53
        • Bell WH
        • Harper RP
        • Gonzales M
        • Cherkashin AM
        • Samchukow ML
        Distraction osteogenesis to widen the mandible.
        Br J Oral Maxillofac Surg. 1997; 35: 11-19
        • Diner PA
        • Kollar EM
        • Viguier E
        • Maurin N
        • Vasquez MP
        Intraoral submerged bidirectional device for mandibular distraction.
        in: Diner P Proceedings First International Congress on Cranial and Facial Bone Distraction Processes. Monduzzi Editore, Bologna1997: 67-74
        • Ilizarov GA
        The tension-stress effect on the genesis and growth of tissues. 1. The influence of stability of fixation and soft-tissue preservation.
        Clin Orthop. 1989; 238: 249-281
        • Ilizarov GA
        The tension-stress effect on the genesis and growth of tissues: II. The influence of the rate and frequency of distraction.
        Clin Orthop. 1989; 239: 263-285
        • Wiltfang J
        • Merten HA
        Knochendehnungsgerät: Mikrohydraulikzylinder zur Durchführung einer bidirektionalen, kontinuierlichen Kallusdistraktion. No. 19645392, IPC: A61B 17/68 (04.11.1996). Deutsches Patentamt, München1998
        • Wiltfang J
        • Kessler P
        • Schultze-Mosgau S
        • Merten HA
        • Günther G
        Continuous bone distraction with the help of a microhydraulic cylinder.
        in: Diner P Proceedings Second International Congress on Cranial and Facial Bone Distraction Processes. Monduzzi Editore, Bologna1999: 35-40
        • Günther G
        Konstruktion und Entwicklung eines miniaturhydraulischen Knochendistraktors zur Streckung eines Schweineunterkiefers. Fakultät für Maschinenwesen, Institutfür Fluidtechnische Antriebe und Steuerungen.
        Rheinisch-Westfälische Technische Hochschule Aachen. 1998;
        • Schmelzeisen R
        • Neumann G
        • von der Fecht R
        Distraction osteogenesis in the mandible with a motor driven plate: a preliminary animal study.
        Br J Oral Maxillofac Surg. 1996; 34: 375-378
        • Ploder O
        • Mayr W
        • Schmetz G
        • Unger E
        • Ewers R
        • Plenk Jr, H
        Mandibular lengthening with an implanted motor-driven device: preliminary study in sheep.
        Br J Oral Maxillofac Surg. 1996; 37: 273-276
        • Hönig JF
        • Merten HA
        Das Göttinger Miniaturschwein (GMS) als Versuchstier in der humanmedizinischen osteologischen Grundlagenforschung.
        Zeitschrift für Zahnärztliche Implantologie. 1993; 2: 237-243
        • Rahn BA
        Die polychrome Sequenzmarkierung des Knochens.
        Acta Nova Leopoldina. 1976; 44: 249-253
        • Donath K
        Säge-Schliff-Technik.
        Fortschr Kiefer Gesichtschir. 1983; 28: 97-101
      1. Schenk, R, K, Gachter, A, Histology of distraction osteogenesis, Brighton, C, TFriedlaender, GLane, J, M, Bone Formation and Repair, Rosemont, American Academy of Orthopedic Surgeons, 1994, 387, 294

        • Saleh M
        • Stubbs DA
        • Street RJ
        • Lang DM
        • Harris SC
        Histologic analysis of human lenghtened bone.
        J Pediatr Orthop. 1993; 2: 16-23
        • Reichel H
        Der diaphysauml;re Knochen nach Kallusdistraktion. Densitometrische, biomechanische und histologische Untersuchungen zur operativen Beinverlängerung. Zuckschwerdt-Verlag, München1996
        • Panikarovski VV
        • Grigorian AS Kaganovich SI
        • Osipian EM
        • Antipova ZP
        Characteristics of mandibular reparative osteogenesis under compression-distraction osteosynthesis: an experimental study.
        Stomatologiia. 1982; 61: 21-25
        • Karp NS
        • JG McCarthy JS
        • Schreiber
        Membranous bone lengthening: a serial histological study.
        Ann Plast Surg. 1992; 29: 2-7
        • Kojimoto H
        • Yasui H
        • Goto T
        Bone lengthening in rabbits by callus distraction: the role ot periosteum and endosteum.
        J Bone Joint Surg. 1988; 70A: 543-549
        • Delloye C
        • Deletortrie G
        • Gautelier L
        Bone regenerate formation in cortical bone during distraction lengthening: an experimental study.
        Clin Orthop. 1990; 250: 34-42